{"id":38920,"date":"2024-09-22T13:22:45","date_gmt":"2024-09-22T10:22:45","guid":{"rendered":"https:\/\/repository.qu.edu.iq\/?p=38920"},"modified":"2024-09-22T13:22:46","modified_gmt":"2024-09-22T10:22:46","slug":"tracking-area-update-procedure-unnecessary-in5g-improving-user-experience-and-offloadingsignaling-overhead","status":"publish","type":"post","link":"https:\/\/repository.qu.edu.iq\/?p=38920","title":{"rendered":"Tracking Area Update Procedure Unnecessary in5G: Improving User Experience and OffloadingSignaling Overhead"},"content":{"rendered":"\n<p class=\"has-text-align-left wp-block-paragraph\">Tracking Area Update Procedure Unnecessary in<br>5G: Improving User Experience and Offloading<br>Signaling Overhead<br>Alaa A. R. Alsaeedy<br>dept. of Electrical and Computer Engineering<br>Colorado State University<br>Fort Collins, USA<br>alaa.alsaeedy@colostate.edu<br>Edwin K. P. Chong<br>dept. of Electrical and Computer Engineering<br>Colorado State University<br>Fort Collins, USA<br>edwin.chong@colostate.edu<br>Abstract\u2014In Long Term Evolution (LTE) and future 5th<br>Generation (5G) wireless networks, the two procedures that are<br>essential to track and locate mobile User Equipments (UEs)<br>within the network are known as Tracking Area Update (TAU)<br>and Paging. These procedures are burdensome for both mobile<br>UEs and serving network\u2014the mobile UEs and serving network<br>always initiate the TAU and Paging procedures, respectively.<br>Because of potentially very high-volume traffic and increasing<br>density of high-mobility UEs, the TAU\/Paging procedure increases<br>not only the accompanied signaling overhead but also the power<br>consumption in the battery-limited UEs. Hence, this problem<br>will become even worse in future 5G networks because the<br>latter is expected to accommodate exceptional services, such as<br>supporting mission-critical systems (close-to-zero latency) and<br>extending battery lifetime (10 times longer).<br>We propose a new solution to solve this problem, named gNBbased<br>UE Mobility Tracking (gNB-based UeMT). This solution has<br>four features achieving 5G goals. First, the mobile UEs will no<br>longer trigger the TAU to report their location changes, giving<br>much more power saving with no signaling overhead. Instead,<br>second, the network elements, gNBs, take over the responsibility<br>of tracking and locating these UEs, giving always-known UE<br>locations. Third, the Paging procedure is markedly improved<br>over the conventional one, providing very fast UE reachability<br>with no Paging messages being sent simultaneously. Fourth, this<br>solution guarantees lightweight signaling overhead with very low<br>Paging delay. To this end, this solution adds no implementation<br>complexity; instead, it exploits the already existed LTE\/5G<br>communication protocols, functions, and measurement reports.<br>Index Terms\u2014tracking area update, paging, RNAU, anchorgNB,<br>AMF, MME, LTE, 5G<\/p>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/repository.qu.edu.iq\/wp-content\/uploads\/sites\/31\/2024\/09\/Tracking-Area-Update.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"\u062a\u0636\u0645\u064a\u0646 Tracking Area Update.\"><\/object><a id=\"wp-block-file--media-95a5d20b-2bdd-4add-992e-4b166164e753\" href=\"https:\/\/repository.qu.edu.iq\/wp-content\/uploads\/sites\/31\/2024\/09\/Tracking-Area-Update.pdf\">Tracking Area Update<\/a><a href=\"https:\/\/repository.qu.edu.iq\/wp-content\/uploads\/sites\/31\/2024\/09\/Tracking-Area-Update.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-95a5d20b-2bdd-4add-992e-4b166164e753\">\u062a\u0646\u0632\u064a\u0644<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Tracking Area Update Procedure Unnecessary in5G: Improving User Experience and OffloadingSignaling OverheadAlaa A. R. Alsaeedydept. of Electrical and Computer EngineeringColorado &#8230; <a class=\"cz_readmore\" href=\"https:\/\/repository.qu.edu.iq\/?p=38920\"><i class=\"fa fa-sign-out\" aria-hidden=\"true\"><\/i><span>\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u0632\u064a\u062f<\/span><\/a><\/p>\n","protected":false},"author":31,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3],"tags":[],"class_list":["post-38920","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/repository.qu.edu.iq\/index.php?rest_route=\/wp\/v2\/posts\/38920","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/repository.qu.edu.iq\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/repository.qu.edu.iq\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/repository.qu.edu.iq\/index.php?rest_route=\/wp\/v2\/users\/31"}],"replies":[{"embeddable":true,"href":"https:\/\/repository.qu.edu.iq\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=38920"}],"version-history":[{"count":1,"href":"https:\/\/repository.qu.edu.iq\/index.php?rest_route=\/wp\/v2\/posts\/38920\/revisions"}],"predecessor-version":[{"id":38922,"href":"https:\/\/repository.qu.edu.iq\/index.php?rest_route=\/wp\/v2\/posts\/38920\/revisions\/38922"}],"wp:attachment":[{"href":"https:\/\/repository.qu.edu.iq\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=38920"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/repository.qu.edu.iq\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=38920"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/repository.qu.edu.iq\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=38920"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}